Axis Health & Diagnostic Services Ltd home

Clinical update, November 2026

A short monthly note for doctors, physician assistants, midwives and nurses who refer to Axis.

10 November 2026 ยท Written by the Axis laboratory team

New at Axis

  • ECG and spirometry are now done at Axis. A 12-lead ECG costs GHS 200, with a report within 24 hours. Spirometry costs GHS 400, with a report within 3 days. Details and preparation.
  • Critical results policy published. The results we phone through, the limits we use and the number we call from are now on one page. Read the policy.
  • A page for each common test. Around 200 tests now have their own page with specimen type, stability and patient preparation. Browse tests A to Z.
  • Screening packs for groups. Pre-employment, school admission and other packs, with a price per person. See the packs.

A test worth knowing: HbA1c, and when not to trust it

World Diabetes Day falls on 14 November, so this month's note is on HbA1c. It is convenient, needs no fasting and reflects glycaemia over roughly the lifespan of a red cell. That last point is also its weakness.

HbA1c assumes a normal haemoglobin and a normal red cell lifespan. In our population, that assumption often fails:

When HbA1c can mislead
SituationEffect on HbA1cWhat to use
Sickle cell disease (SS, SC)Unreliable, usually falsely low because red cells survive for a shorter timeFasting glucose, OGTT or self-monitored glucose
Haemoglobin variants (AS, AC)May be affected, depending on the assay methodInterpret with care. Confirm with glucose-based tests if the result does not fit the clinical picture
Haemolysis, including G6PD deficiency after a haemolytic episodeFalsely lowGlucose-based tests
Recent blood loss or transfusionUnreliable for about 3 monthsGlucose-based tests
Iron deficiency anaemiaMay be falsely highTreat the anaemia and repeat, or use glucose-based tests
PregnancyLower than expected, and not recommended for diagnosing gestational diabetesOGTT
Chronic kidney disease, especially on erythropoietinUnreliableGlucose-based tests

In practice: where the haemoglobin genotype is unknown and an HbA1c does not match the patient's glucose readings or symptoms, request a haemoglobin electrophoresis and rely on fasting glucose or an OGTT. Writing the genotype on the request form, where known, helps us flag results that need caution.

WHO diagnostic thresholds for reference: fasting plasma glucose 7.0 mmol/L or above; 2-hour plasma glucose 11.1 mmol/L or above after a 75 g load; HbA1c 6.5% (48 mmol/mol) or above. In an asymptomatic patient, confirm with a second test.

Help us help your patients

  • Write a phone number that will be answered on every request, so critical results reach you.
  • For fasting tests, tell the patient to fast for 8 to 12 hours and come in the morning.
  • For timed tests, write the time of the last dose or the day of the cycle.
  • Patients who cannot travel can book home collection.

This update is for health professionals and supports, but does not replace, clinical judgement and current guidelines.